Message: RE: Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector () Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None RE: Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector () 

Forum: Run Management
Re: Question Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector () (Alan Shippen)
Date: 13 Mar, 2007
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

-----Original Message-----
From: Alan [mailto:b.a.shippen@lancaster.ac.uk] 
Sent: Monday, March 12, 2007 8:53 PM
To: PublicHyperNews@slac.stanford.edu
Subject: Segmentation Fault in
G4RToEConvForGamma::BuildAbsorptionLengthVector ()

*** Discussion title: Run Management
Email replies to PublicHyperNews@slac.stanford.edu must include:
  In-Reply-To: <"/runmanage/181"@geant4-hn.slac.stanford.edu>
  Subject: ...change this to be about your reply.

Hello,
      I get the above error message every time i run the /run/beamOn
command Here is the output from gdb:

Program received signal SIGSEGV, Segmentation fault. 0x00000000005b49be
in G4RToEConvForGamma::BuildAbsorptionLengthVector ()

and from backtrace:

#0  0x00000000005b49be in
G4RToEConvForGamma::BuildAbsorptionLengthVector ()
#1  0x00000000005b71d6 in G4VRangeToEnergyConverter::Convert ()
#2  0x00000000005b2d5d in G4ProductionCutsTable::UpdateCoupleTable ()
#3  0x0000000000512c34 in G4RunManagerKernel::RunInitialization ()
#4  0x0000000000515ced in G4RunManager::RunInitialization ()
#5  0x0000000000513875 in G4RunManager::BeamOn ()
#6  0x0000000000518221 in G4RunMessenger::SetNewValue ()
#7  0x00000000006a5cb4 in G4UIcommand::DoIt ()
#8  0x00000000006ad02b in G4UImanager::ApplyCommand ()
#9  0x00000000004b25cb in G4UIterminal::ExecuteCommand () #10
0x00000000004b3f01 in G4UIterminal::SessionStart ()
#11 0x0000000000406960 in main ()

I personally assumed that it would be a problem with the range cuts but
having studied other examples i can 't find anything wrong (in fact the
whole physics process class is copied from example N03). As I am
entirely new to developing with geant4 i'm all out of ideas of where to
look now. Does anybody have any suggestions?

Thank You for Your Time

Alan

Hello,

Something is wrong in your PhysicsLIst. Compare in details N03 PhysLists
and your own.

VI

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: RE: Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector ()   (Alan - 13 Mar, 2007)
(_ None: RE: Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector ()   (Makoto Asai - 13 Mar, 2007)
 Add Message Add Message
to: "RE: Segmentation Fault in G4RToEConvForGamma::BuildAbsorptionLengthVector ()"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]