Message: Re: Bearden Data Set for Deexcitation Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: Bearden Data Set for Deexcitation 

Forum: Physics List
Re: Question Bearden Data Set for Deexcitation (Richard Foster)
Re: Idea Re: Bearden Data Set for Deexcitation (Vladimir Ivanchenko)
Re: Question Re: Bearden Data Set for Deexcitation (Richard Foster)
Date: 06 Nov, 2017
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello,

I am using Geant4 10.3p03 and the example code of

$G4INSTALL/examples/extended/electromagnetic/TestEm5

There is a macro fluo.mac, which is changed to a variant shown in the attachment.

With this macro for the batch mode Bearden data for level energies are enabled. Please note, atomic ed-excitation data are uploaded once and shared between all threads and all runs. It is not possible to change the data between runs at G4State_Idle. Before the first run you need to tell Geant4 what atomic ed-excitation data are needed. By the way, this is valid to other data type as well.

What can be changed between runs are flags, for example, one can enable, disable sampling of fluorescence and/or Auger electron emission.

VI

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2017/11/06/09.45-64030-fluo1.mac

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Sad: Re: Bearden Data Set for Deexcitation   (Richard Foster - 14 Dec, 2017)
 Add Message Add Message
to: "Re: Bearden Data Set for Deexcitation"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]