Message: Enable/Disable internal conversion Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Enable/Disable internal conversion 

Forum: Physics List
Date: 21 Jun, 2017
From: Delaune Olivier <Delaune Olivier>

Dear GEANT4 experts, I am looking for a way to disable the internal conversion mechanism. I found the method SetICM in the G4RadioactiveDecay class. However, it seems to not work since it does not change anything either I set it to "true" or "false". It is the same (nothing change in my simulation results) if I use /grdm/icm true (or false). Basically I want Xe131m to decay; it is a mestable level at 164 keV with an internal conversion coefficient of about 50. In this case, if I set icm to false, GEANT4 still continues to generate electrons (instead of gammas). Looking at the code of G4RadioactiveDecay.cpp, it seems that this parameter is not use.

Am I doing something wrong or is it a bug (or maybe it is not yet implemented). Is there a way to disable internal conversion?

I use GEANT 4.10.3 patch1

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: Enable/Disable internal conversion   (Vladimir Ivanchenko - 02 Jul, 2017)
(_ Idea: Re: Enable/Disable internal conversion   (Delaune Olivier - 05 Jul, 2017)
 Add Message Add Message
to: "Enable/Disable internal conversion"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]