Message: Re: Low Energy ions, comparison with SRIM Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Low Energy ions, comparison with SRIM 

Forum: Physics List
Re: Feedback Low Energy ions, comparison with SRIM
Re: Idea Re: Low Energy ions, comparison with SRIM (Vladimir Ivanchenko)
Re: More Re: Low Energy ions, comparison with SRIM
Re: Idea Re: Low Energy ions, comparison with SRIM (Vladimir Ivanchenko)
Date: 11 Mar, 2017
From: <Synthex>

Dear Vladimir; Running the TestEm7 with your macro gives me values compatible with mine: ~25nm for yours, 24.7nm for mine, both running 10 000 F19 ions at 10keV, using NIST WATER material, option4 standard em, or Shielding. I only care about the projected range of the ions when reaching 0eV: print results if(edep=egamma && egamma>0). See my output_r333 file that shows the end of life parameters of 100 ions. SRIM also prints the «ion range, projected on a Y plane», so not the track length but the range, as we do. Here is a printscreen of the same bombardment configuration with TRIM, as with «Stopping/Range table subroutine», range is about 41nm. This is very interesting. Thank you again! PS: to run your .in file, change tallyPosition0 to tallyPosition 1 I cannot find any difference between your 2 macros. Attachment: http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2017/03/11/03.37-80048-SRIM_out.png http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2017/03/11/03.37-24354-Output_r333.dat

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 News: Re: Low Energy ions, comparison with SRIM   (Synthex - 14 Mar, 2017)
(_ Idea: Re: Low Energy ions, comparison with SRIM   (Vladimir Ivanchenko - 18 Apr, 2017)
 Add Message Add Message
to: "Re: Low Energy ions, comparison with SRIM"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews