Hello,

you need to be sure that NIST Geant4 materials are used : G4_Li and G4_WATER.

Also you need to take Opt4 EM physics. The example may be seen in $G4INSTALL/examples/extended/hadronic/Hadr00 and Hadr01. You may define in these examples Physics Lists with different EM configurations:

FTFP_BERT_EMZ, QBBC_EMZ, Shielding_EMZ