Message: Re: Minimum step size for ionization in a gas Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: Minimum step size for ionization in a gas 

Forum: Physics List
Re: None Minimum step size for ionization in a gas (Alfredo Castaneda)
Re: Idea Re: Minimum step size for ionization in a gas (Vladimir Ivanchenko)
Re: None Re: Minimum step size for ionization in a gas (Alfredo Castaneda)
Date: 10 Dec, 2016
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello,

TestEm8 is an example demonstrating how it is possible simulate gaseous detectors. Accuracy of default Geant4 simulation in same part of such detectors may be not very high. A typical recommendation is to provide more steps within gas gap (normally 2 steps is enough). This may be done using several methods. Partly it is should in TestEm8.

If you use reference Physics List and G4PhysListFactory (see $G4INSTALL/examples/extended/hadronic/Hadr00), then FTFP_BERT_EMY should provide better results than FTFP_BERT.

VI