Message: Neutron HP Process in QGSP_INCLXX_HP Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Neutron HP Process in QGSP_INCLXX_HP 

Forum: Physics List
Date: 22 Feb, 2016
From: Robin Tesse <Robin Tesse>

Dear GEANT4 users,

During a simulation, I want to compare these three models : QGSP_BERT_HP, QGSP_BIC_HP and QGSP_INCLXX_HP. 

My simulation data are the following : 

- Geant4.10.01 version
- Cylindric target in graphite (L = 30cm; Radius = 16.55 cm)
- 230 MeV proton beam
- Physics :  QGSP_BERT_HP, QGSP_BIC_HP and QGSP_INCLXX_HP

I look the energy of the emitted neutron and I obtain the figure below. 

I'am a bit disappointed because  as you can see, QGSP_INCLXX_HP doesn't emit neutron below 1e-6 MeV. 

I was wondering if the neutron HP model is correctly implemented in GEANT4 or if the problem comes from elsewhere.

Thank you in advance

Best regards

Tesse Robin

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2016/02/22/23.17-55390-CarbonSpectrumModel.pdf