Idea Re: the process number setting 

Forum: Physics List
Re: Question the process number setting (HuangHong)
Date: 30 Oct, 2015
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello,

this method to define Physics List is working normally but is not anymore the recommended one. In $G4INSTALL/source/physics_list/constructors/electromagnetic this is not used anymore. Instead G4PhysicsListHelper is recommended. Moreover, we recommend to use physics constructors from this subdirectory and not make custom Physics List.

Concerning numbers: "-1" means process is not active, if a number is not negative this means the order - processes are called at each step one by one and correct order should be defined. More details on this in the Application Developer manual and in geant4 tutorials.

VI