Message: the process number setting Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question the process number setting 

Forum: Physics List
Date: 26 Oct, 2015
From: HuangHong <HuangHong>

I have read a geant4 file at the web: http://www-geant4.kek.jp/lxr/source//physics_lists/lists/include/LBE.icc#L329 .I know these 3 numbers correspond to 3 stage of interactions: AtRest, AlongTheStep, PostStep and i konw -1 = not implemented, then ordering according to the web file. However I can not understand the meaning of relative magnitudes of the number as follows. Could anyone give some explation about "-3, 2, 3, 4"?

 else if (particleName == "e+") 
354       {
355   //positron
356       G4eMultipleScattering* msc = new G4eMultipleScattering();
357       //msc->AddEmModel(0, new G4UrbanMscModel());      
358       msc->SetStepLimitType(fUseDistanceToBoundary);
359       pmanager->AddProcess(msc,                   -1, 1, 1);
360       G4eIonisation* eIoni = new G4eIonisation();
361       eIoni->SetStepFunction(0.2, 100*CLHEP::um);      
362       pmanager->AddProcess(eIoni,                 -1, 2, 2);
363       pmanager->AddProcess(new G4eBremsstrahlung, -1,-3, 3);      
364       pmanager->AddProcess(new G4eplusAnnihilation,0,-1, 4);
365       }

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: the process number setting   (Vladimir Ivanchenko - 30 Oct, 2015)