Message: Shielding list modifications for low energy Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Shielding list modifications for low energy 

Forum: Physics List
Date: 13 Mar, 2013
From: Javier Tiffenberg <Javier Tiffenberg>

Hi, I'm trying to simulate the background radiation spectrum of a Ge detector surrounded by a thin layer of pure copper and a lead shield contaminated with 210Pb and 238U. I need to be able to get an accurate representation of the fluorescence x-ray produced in the lead and copper.

I made a physics list based on the "Shielding" list but I replaced the EmStandardPhysics list:

  this->RegisterPhysics( new G4EmStandardPhysics(verbose));

by the Livermore list:

  this->RegisterPhysics( new G4EmLivermorePhysics(verbose));
  G4EmProcessOptions emOptions;
  emOptions.SetFluo(true); // To activate deexcitation processes and fluorescence
  emOptions.SetAuger(true); // To activate Auger effect if deexcitation is activated
  emOptions.SetPIXE(true); // To activate Particle Induced X-Ray Emission (PIXE)

I'm also setting the production cuts to 0.001mm.

Is this the way to obtain the most accurate results? The spectrum I get doesn't seem to reproduce the expected florescence peaks. I'm using geant4.9.5.p02

Thanks a lot for your help.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: Shielding list modifications for low energy   (Vladimir Ivanchenko - 07 Apr, 2013)
 Add Message Add Message
to: "Shielding list modifications for low energy"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews