Hello,

In Geant4 9.5 and 9.6beta de-excitation module is included in all EM builders of reference Physics Lists but is not enabled in all for fluorescence and disebled for Auger electrons. To enable de-excitation one has to add UI command

/run/initialise /process/em/fluo true /process/em/auger true

Note, that production threshold for electrons and gammas are checked - low-energy e- and g will not be produced.