Message: Re: Dose increases by 30% switching from G4.9.3.p02 to G4.9.4.p01 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Dose increases by 30% switching from G4.9.3.p02 to G4.9.4.p01  

Forum: Physics List
Re: Question Dose increases by 30% switching from G4.9.3.p02 to G4.9.4.p01 (Daniel Matthiń)
Date: 18 Mar, 2011
From: Makoto Asai <Makoto Asai>

Dear Daniel,

Please let me confirm that you do not use any sort of scorers in cylindrical shape. We identify a bug in G4PSDoseDeposite which scores dose, and the problem occurs only for the cylindrical scoring mesh. This bug seems to be introduced at v9.4. If you do not use scoring functionality, or if you use it only for the box, please discard this inquiry.

Kind regards, Makoto Asai