Hi everybody,
I'm trying to simulate a muSR experiment with Geant4. Everything works as expected but spin polarization during implantation: I want muon spin to remain (almost) polarized during energy loss in sample (mu ionization process and mu multiple scattering) but, when at rest in the sample, muon spin polarization is completely lost.

I'm shooting ~4MeV muons to an iron sample.

Is there a way to tell ionization process not to touch the spin?

Thanks in advances,
regards,
Pietro Bonfa'

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: Muon Ionization spin problem   (Vladimir Ivanchenko - 25 Jan, 2011)
(_ Question: Re: Muon Ionization spin problem   (Pietro Bonfa' - 25 Jan, 2011)
1 Idea: Re: Muon Ionization spin problem   (Vladimir Ivanchenko - 25 Jan, 2011)
2 None: Re: Muon Ionization spin problem   (Kevin Lynch - 25 Jan, 2011)
1 Question: Re: Muon Ionization spin problem   (Pietro Bonfa' - 26 Jan, 2011)