Message: Re: RadioactiveDecay and *** G4Exception: Aborting execution *** Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: RadioactiveDecay and *** G4Exception: Aborting execution *** 

Forum: Physics List
Re: Warning RadioactiveDecay and *** G4Exception: Aborting execution *** (sdreda)
Date: 03 Apr, 2008
From: Vladimir IVANTCHENKO <vnivanch@mail.cern.ch>

On Thu, 3 Apr 2008, sdreda wrote:

> *** Discussion title: Physics List
> Email replies to PublicHyperNews@slac.stanford.edu must include:
>   In-Reply-To: <"/phys-list/470"@geant4-hn.slac.stanford.edu>
>   Subject: ...change this to be about your reply.
> 
>    Hello, I am simulating radioactive Decay products from the interaction of 280 Mev/U carbone with PMMA target.
> 
>   After I build my Elastic and Inelastic process for generic Ion, I add Radioactive Decay model to it (I looked the exRDM example )
> 
>   In my PhysicsList I have :
> 
>   #include "G4RadioactiveDecay.hh"
>   #include "G4Decay.hh"
> 
>   G4ProcessManager* pManager = particle->GetProcessManager();
>   G4String particleName = particle->GetParticleName();
> 
>   else if (particleName=="GenericIon"){
>   .... (Elastic and Inelastic process)
> 
>    // Add RadioactiveDecay Process
>    G4RadioactiveDecay*  theRadioactiveDecay = new G4RadioactiveDecay();
>    pManager->AddProcess(theRadioactiveDecay, 0, -1, 3);   
>    pManager ->SetProcessOrdering(theRadioactiveDecay, idxPostStep);
>    pManager ->SetProcessOrdering(theRadioactiveDecay, idxAtRest);

Here I would choose between (..,0,-1,3) and SetProcessOrdering but it is 
not an error.

> 
> } And I have also built Decay of unstable particle with "G4Decay" in
> ::ConstructGeneral();
> 
> in my macro file I have :
> 
> /control/verbose 0 /run/verbose 0 /event/verbose 0 /tracking/verbose 0
> 
> I have not error in compile, but in simulation after 1000 event it
> stoped and make me these lines:
> 
> G4AugerData - data file:
> /usr/local/geant4.8.2/data/G4EMLOW4.1/auger/au-tr-pr-6.dat not found
> 
> *** G4Exception: Aborting execution *** Abandon
> 
> Does anybody have any suggestions? I will appreciate if someone will
> write his/her ideas about this. Maybe I am doing something wrong in the
> PhysicsList...
> 
>  Thank you,
> 
>  Reda.

Your problem not in Radioactive decay but in Low-energy EM package - the 
required data file is not found out. You can switch off radioactive decay 
and will have the same problem.

VI

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: RadioactiveDecay and *** G4Exception: Aborting execution ***   (sdreda - 04 Apr, 2008)
(_ None: Re: RadioactiveDecay and *** G4Exception: Aborting execution ***   (Vladimir IVANTCHENKO - 04 Apr, 2008)
(_ None: Re: RadioactiveDecay and *** G4Exception: Aborting execution ***   (sdreda - 10 Apr, 2008)
 Add Message Add Message
to: "Re: RadioactiveDecay and *** G4Exception: Aborting execution ***"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]