Message: question about muon capture in water Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None question about muon capture in water 

Forum: Physics List
Date: 15 Aug, 2006
From: <luhq@mail.ihep.ac.cn>

Hi everyone,

I met a question when simulating mu- capture in Water. However, when the kinetic energy of primary mu- is 1.2GeV, there always is a segmentation and the tracking information shows that a N15 is produced in Water as a daughter particle of the primary mu-:

*********************************************************************************************************
* G4Track Information:   Particle = N15[0.0],   Track ID = 194153,   Parent ID = 1
*********************************************************************************************************

Step#    X(mm)    Y(mm)    Z(mm) KinE(MeV)  dE(MeV) StepLeng TrackLeng  NextVolume ProcName
    0    -57.9      349 -2.06e+03     0.435        0        0         0       water initStep
    1    -57.9      349 -2.06e+03     0.435        0 1.8e+308  1.8e+308       water User Limit

I don't know why, the track length is so long. When the kinetic energy isn't 1.2GeV, the program run well. Is it a bug?

Many thanks. H.Q. Lu

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re:question about muon capture in water   (pwijesinghe1@student.gsu.edu - 12 Sep, 2006)