Message: PAI for G4.8.0 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None PAI for G4.8.0 

Keywords: PAI deltaTkin
Forum: Physics List
Date: 23 Jan, 2006
From: Daniel Kramer <daniel.kramer@cern.ch>

Hi, I am testing the PAI model for a thin foil at very low energies and very often get the following message:

>>
Tkin of secondary e- <= 0. G4PAIModel::SampleSecondary::deltaTkin = 0 Set G4PAIModel::SampleSecondary::deltaTkin = 1e-05

Is it just a probability issue with no real impact on the simulation? (it's set to 1e-05 anyway) or should I check my code..?

>>

With G4.7.1 I had not a single secondary electron produced below ~150 keV of primary protons by the PAI model (the cuts were set veery low but correctly).

Now I have a lot finally!