Message: Message no. 197 continued Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Message no. 197 continued 

Forum: Physics List
Date: 11 Jan, 2006
From: Ma yunzhi <Ma yunzhi>

This message continues the message no. 197:

The e- CSDA range given by LOW ENERGY simulation is much larger than
that given by STANDARD simulation and the value published by ICRU
and EGSnrc.

===>>>   537 mum >> 143 mum

            ^         ^
          lowen     standard, ICRU,EGSnrc


Something must be wrong with G4LowEnergyIonization!

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Message no. 197 continued   (liuhm@ihep.ac.cn - 11 Jan, 2006)
1 None: BUT instruction of message 183 doesn't give the right SCDA range   (y.z. ma - 12 Jan, 2006)
(_ None: Re: BUT instruction of message 183 doesn't give the right SCDA range   (Vladimir IVANTCHENKO - 15 Jan, 2006)
3 None: Re: Message no. 197 continued   (michel maire - 20 Jan, 2006)
 Add Message Add Message
to: "Message no. 197 continued"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]