Message: problem with radioactive decay and LowEnergy PhisicsList Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None problem with radioactive decay and LowEnergy PhisicsList 

Keywords: Radioactive decay LowEnergy PhysicsList
Forum: Physics List
Date: 12 Oct, 2005
From: COURTINE Fabien <courtine@clermont.in2p3.fr>

Hello,
I use Geant4.7.0 and i want to do the decay of 137Cs.
First i have simulated gamma with single energy without decay with LowEnergy PhysicsList.
I hace calculated  efficiency at 32 keV and 662 keV. Then, i try to do the same thing with radioactive deacy with exrdm example.
When i use the Standard PhysicsList no problem, the efficiency at 32 and 662 keV are the same with single energy gamma.
But when i use the LowEnergy PhysicsList the efficiency are different. I think there is a problem with the energy loss :
*********************************************************************************************************
* G4Track Information:   Particle = gamma,   Track ID = 6,   Parent ID = 2
*********************************************************************************************************

Step#    X(mm)    Y(mm)    Z(mm) KinE(MeV)  dE(MeV) StepLeng TrackLeng  NextVolume ProcName
    0 8.12e-11 1.58e-10 -2.25e-10     0.662        0        0         0      Target initStep
    1  0.00286 -0.00035    0.005     0.662        0  0.00577   0.00577       World Transportation
    2  0.00993 -0.00121   0.0173     0.662        0   0.0143      0.02    Detector Transportation
    3     8.91    -1.09     15.6     0.564   0.0979     17.9        18    Detector LowEnCompton
    4     9.87    -2.03     16.7     0.505   0.0588     1.77      19.7    Detector LowEnCompton
    5     27.9    -31.4     27.3     0.268    0.237       36      55.8    Detector LowEnCompton
    6     27.4    -37.2     16.4     0.193   0.0744     12.4      68.2    Detector LowEnCompton
    7       32    -37.7       15     0.118   0.0752     4.82        73    Detector LowEnCompton
    8     31.3    -36.6     15.6         0 0.000125     1.46      74.4    Detector LowEnPhotoElec

*********************************************************************************************************
* G4Track Information:   Particle = gamma,   Track ID = 8,   Parent ID = 6
*********************************************************************************************************

Step#    X(mm)    Y(mm)    Z(mm) KinE(MeV)  dE(MeV) StepLeng TrackLeng  NextVolume ProcName
    0     31.3    -36.6     15.6    0.0109        0        0         0    Detector initStep
    1     31.3    -36.7     15.6         0   0.0014   0.0691    0.0691    Detector LowEnPhotoElec

*********************************************************************************************************
* G4Track Information:   Particle = e-,   Track ID = 9,   Parent ID = 8
*********************************************************************************************************

Step#    X(mm)    Y(mm)    Z(mm) KinE(MeV)  dE(MeV) StepLeng TrackLeng  NextVolume ProcName
    0     31.3    -36.7     15.6   0.00954        0        0         0    Detector initStep
    1     31.3    -36.7     15.6         0   0.0191 0.000815  0.000815    Detector LowEnBrem

*********************************************************************************************************
* G4Track Information:   Particle = e-,   Track ID = 7,   Parent ID = 6
*********************************************************************************************************

Step#    X(mm)    Y(mm)    Z(mm) KinE(MeV)  dE(MeV) StepLeng TrackLeng  NextVolume ProcName
    0     31.3    -36.6     15.6     0.107        0        0         0    Detector initStep
    1     31.3    -36.6     15.6         0    0.214   0.0484    0.0484    Detector LowEnBrem

*********************************************************************************************************
* G4Track Information:   Particle = Ba137[0.0],   Track ID = 5,   Parent ID = 2
*********************************************************************************************************
So we can see that for electron the energy loss is higher than their initial energy. 
Does it means that radioactve decay doesn't work with LowEnergy package? Can we hope that radioactive decay works with LowEnergye package.
Thanks for your reply.
Fabien

Inline Depth:
 1 1
 All All
Outline Depth: