Date: Dec 29, 04:19
From: Baljeet Seniwal <Baljeet Seniwal>

Hello Everyone

I am trying to model electron spectrum of I125. 
 In Physics list I used G4RadioactiveDecayPhysics class and used G4EmDNAPhysics. I constructed particles like leptons,bosons, mesons, Baryons, Ions and short lived constructors.
I also constructed processes for G4EmDNAPhysics, registered processes for radioactive decay.
I used cut off of 1 nm and 10 eV.
I also used
/process/em/deexcitationIgnoreCut true
/process/em/fluo true
/process/em/auger true
/process/em/augerCascade true
/process/em/pixe true

 I used neutral I125 as a source and I distributed it uniformly inside the spheres one by one. And calculating S-value for different source and target combinations. I used following command for I125
/gun/particle ion
/gun/ion 53 125

But still I am finding huge difference in my results and literature. Can anyone please help me out of this? Any kind of help will be appreciated.

warm regards Balli

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: I125   (Baljeet Seniwal - Jan 01, 14:01)
2 None: Re: I125   (Baljeet Seniwal - Jan 01, 14:05)
1 Idea: Re: I125   (Vladimir Ivanchenko - Jan 03, 02:16)
2 Idea: Re: I125   (Vladimir Ivanchenko - Jan 05, 03:10)
1 Idea: Re: I125   (Vladimir Ivanchenko - Jan 05, 03:46)
 Add Message Add Message
to: "I125"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]