Message: Limiting number of runs based on absorbed dose. Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Limiting number of runs based on absorbed dose. 

Forum: Particles
Date: 02 May, 2012
From: Adam Spindler <Adam Spindler>

Hi all, I am currently using the GAMOS distro to simulate the effects of protons and x-rays in cells when Gold Nanoparticles are present. In order to compare them nicely, I wanted to exposed the volumes to an equal amount of radiation. Since the Protons and X-rays have very different energies (3MeV and 200keV respectively) I was wondering if there was a way to run the simulation until a certain amount of dose is absorbed (say 1 gray, for example).

Thanks for the help :D

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Limiting number of runs based on absorbed dose.   (michel maire - 03 May, 2012)