Message: Re: Defining a micro curie source Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Defining a micro curie source 

Forum: Particles
Re: None Defining a micro curie source (Davinder Siwal)
Re: Feedback Re: Defining a micro curie source (Gumplinger Peter)
Date: 07 Jul, 2011
From: Davinder Siwal <Davinder Siwal>

Thanks Peter

Actually My source is placed behind 1mm hole of lead collimter. The lead plate is 20mm thick and and 10*cm away from the germanium detector surface so it is taking very long time(4-5 days) to give a good statistics . Is there is any faster way of doing this.

With Regard

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: Defining a micro curie source   (Gumplinger Peter - 07 Jul, 2011)
(_ None: Re: Defining a micro curie source   (Davinder Siwal - 08 Jul, 2011)
(_ Feedback: Re: Defining a micro curie source   (Gumplinger Peter - 08 Jul, 2011)
(_ None: Re: Defining a micro curie source   (Davinder Siwal - 09 Jul, 2011)
(_ Feedback: Re: Defining a micro curie source   (Gumplinger Peter - 11 Jul, 2011)
 Add Message Add Message
to: "Re: Defining a micro curie source"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews