Hi, Again!

I currently have some doubts about some parameters in the detector construction in the example OpNovice, for be more precise:

G4double energy_water[] = {
     1.56962*eV, 1.58974*eV, 1.61039*eV, 1.631 .....  };

  //assume 100 times larger than the rayleigh scattering for now.
  G4double mie_water[] = { 167024.4*m, 158726.7*m, 150742*m, ....};

  assert(sizeof(mie_water) == sizeof(energy_water));

  // gforward, gbackward, forward backward ratio
  G4double mie_water_const[3]={0.99,0.99,0.8};

I understand that energy_water is related to the mie_water, but nothing more, so..

1.what is the physical meaning or what is refer the energy_water and the mie_water, why are they related? 2.the same with G4double mie_water_const[3]={0.99,0.99,0.8};, what is this?

Looking in the forum i found the same question, but it was not answered most probably because is in another no related section, (http://hypernews.slac.stanford.edu/HyperNews/geant4/get/EduApp/29.html). so i repost the question.

I will really appreciate any help you can provide.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Feedback: Re: Doubts about some parameters in Detector constructiion (OpNovice)   (Gumplinger Peter - 23 Nov, 2017)
(_ Question: Re: Doubts about some parameters in Detector constructiion (OpNovice)   (Jaiver Salazar - 29 Nov, 2017)
(_ Note: Re: Doubts about some parameters in Detector constructiion (OpNovice)   (Jaiver Salazar - 29 Nov, 2017)
 Add Message Add Message
to: "Doubts about some parameters in Detector constructiion (OpNovice)"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews