Message: Re: RINDEX in world volume and subvolume causes hang Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: RINDEX in world volume and subvolume causes hang 

Forum: Processes Involving Optical Photons
Re: None RINDEX in world volume and subvolume causes hang (Remy Prechelt)
Date: 12 Sep, 2017
From: Remy Prechelt <Remy Prechelt>

After more investigations, it is apparent that this simulation works if the index of refraction of the G4Box is chosen such that the Cerenkov angle is less than the critical angle for total internal reflection. Once I hit the critical angle, the simulation hangs. The volume is a thin microscope slide and as far as I can calculate, totally reflecting of one face should not cause the photons to indefinitely reflect.

Is there a method to limit the number of steps taken by an opticalphoton to investigate why total internal reflection on the one surface is causing my simulation to hang?

 Add Message Add Message
to: "Re: RINDEX in world volume and subvolume causes hang"

 Subscribe Subscribe