Message: Re: Additional energy deposited in scintillators Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Re: Additional energy deposited in scintillators 

Forum: Processes Involving Optical Photons
Re: Question Additional energy deposited in scintillators (Michael Hubbard)
Re: Idea Re: Additional energy deposited in scintillators (Michael Hubbard)
Re: Agree Re: Additional energy deposited in scintillators (Gumplinger Peter)
Date: 15 May, 2017
From: Michael Hubbard <Michael Hubbard>

Hello again,

I have implemented a fix for the optical photon energy conservation as suggested. In LXeScintSD::ProcessHits

  G4String PID = aStep->GetTrack()->GetDefinition()->GetParticleName();    
  if(PID=="opticalphoton" || edep==0.) return false;

However I have just transferred over from a sequential version of Geant4 to multithreaded one. During this process I have noticed the LXe example double counts, the energy deposited in the scintillator.

For example:

In Sequential, 1 MeV gamma: Total energy deposition in scintillator : 1000 (keV)

In Multithreaded, 1 MeV gamma Total energy deposition in scintillator : 2000 (keV)

Any suggestions for a fix?

Many thanks

 Michael

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 News: Re: Additional energy deposited in scintillators   (Andrea Dotti - 31 May, 2017)
(_ Ok: Re: Additional energy deposited in scintillators   (Michael Hubbard - 01 Jun, 2017)
 Add Message Add Message
to: "Re: Additional energy deposited in scintillators"

 Subscribe Subscribe