Message: Re: Wrong photon yield for alpha particles Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Ok Re: Wrong photon yield for alpha particles 

Forum: Processes Involving Optical Photons
Re: Question Wrong photon yield for alpha particles (Liyong Zhang)
Date: 31 Aug, 2016
From: Liyong Zhang <Liyong Zhang>

Hi All,

I found the mistake I made. It is the SetBirksConstant(0.126*mm/MeV) function in DetectorConstruction that attenuated the photon yield. This function cause a non linearity between photon number and deposited energy. And the 0.126*mm/MeV value is for organic scintllator, not for the ZnS I used.

Thank you so much!