Message: Re: general particle source module Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Disagree Re: general particle source module 

Forum: Processes Involving Optical Photons
Date: 25 May, 2006
From: Gumplinger Peter <Gumplinger Peter>

Px, Py, Pz are the Cartesian components of a transverse polarization vector (linear polarization). I don't think the command checks for the validity of the input; i.e. you MUST make sure that the three components are normalized to one and perpendicular to the photon direction. (nothing to do with the Stokes Parameters or the Jones Vectors)

So, light linearly polarized in the horizontal direction, would be 1 0 0 if the photon travels in the yz-plane