Message: Re: CsI caloriemeter, an event never ends! Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Re: CsI caloriemeter, an event never ends! 

Forum: Processes Involving Optical Photons
Re: Question CsI caloriemeter, an event never ends! (Hanjin Kim)
Re: Feedback Re: CsI caloriemeter, an event never ends! (Gumplinger Peter)
Re: Ok Re: CsI caloriemeter, an event never ends! (Hanjin Kim)
Re: Feedback Re: CsI caloriemeter, an event never ends! (Michael H. Kelsey)
Date: 28 Jan, 2018
From: Sahar <Sahar >

Hi
I know this post is from 6 years ago! but I was searching in forum to find if I can find my answer or not .I saw this post so Did you know what is the right value for absorption length and refractive index of CsI(TL) for the energy spectrum ?

const G4int NUMENTRIES_Caesiumiodide = 7;

  G4double ENERGY_Caesiumiodide[NUMENTRIES_Caesiumiodide] = {
    1.77*eV,1.9*eV,2.06*eV,2.25*eV,2.45*eV,2.75*eV,3.1*eV
  };
  G4double RefractiveIndex1[nEntries] =
            { 1.8,1.8,1.8,1.8,1.8,1.8,1.8};
 G4double Absorption1[nEntries] =
       {100*cm,100*cm,100*cm ,100*cm,100*cm,100*cm,100*cm};

in my detector construction refractive index 1.8 and absorption length 100cm are for maximum wavelength .I don't know what is the right value for other energies ?

Thanks very much

 Add Message Add Message
to: "Re: CsI caloriemeter, an event never ends!"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews