Hello Chibueze,

You need to take a close look at the logic/code in LXeEventAction::EndOfEventAction. You'll see that the reconstructed position is calculated from:

      reconPos+=(*PHC)[i]->GetPMTPos()*(*PHC)[i]->GetPhotonCount();

Now, if all of your PMTs are positioned at the same z location; e.g. (*PHC)[i]->GetPMTPos() returns the same z for all PMTs, this logic will not give you a 'depth of interaction' information. You will have to implement a different logic - one that you have to devise and code - whereby the GetPhotonCount is used to determine which cone position provides the most likely photon count sharing between your PMTs as the one that's observed.

Cheers, Peter