Message: A scintillator sensitive to both neutrons and gammas Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None A scintillator sensitive to both neutrons and gammas 

Forum: Processes Involving Optical Photons
Re: Question A scintillator sensitive to both neurons and gammas (Clarisse)
Date: 22 Apr, 2009
From: Paul Nicholas Colin Gloster <Paul Nicholas Colin Gloster>

Must you use a scintillator? Would a CdZnTe semiconductor suffice instead?

A paper re thermal neutrons and CdZnTe is
McGregor,_D.S. and_Rojeski,_R.A., "Performance of CdZnTe geometrically weighted semiconductor Frisch grid radiation detectors", 1999
and a number of papers re gamma photons and CdZnTe and Geant have been written.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Question: Re: A scintillator sensitive to both neutrons and gammas   (Clarisse - 22 Apr, 2009)
1 None: Re: A scintillator sensitive to both neutrons and gammas   (Paul Nicholas Colin Gloster - 22 Apr, 2009)
2 Feedback: Re: A scintillator sensitive to both neutrons and gammas   (Gumplinger Peter - 06 May, 2009)
3 Question: Re: A scintillator sensitive to both neutrons and gammas   (Steve Heaton - 29 Nov, 2011)
1 Feedback: Re: A scintillator sensitive to both neutrons and gammas   (Gumplinger Peter - 29 Nov, 2011)