Message: Re: How to decrease the time used per event of optical process of plastical scintillation? Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Feedback Re: How to decrease the time used per event of optical process of plastical scintillation? 

Keywords: secrease tme optical plastical scintillation
Forum: Processes Involving Optical Photons
Date: 10 Jan, 2008
From: Gumplinger Peter <Gumplinger Peter>

Hello Xiaoxiao Li,

Not much you can do, except forego statistical precision by reducing the yield from 8000./MeV to 800./MeV. You should now get about 6 photons collected at the PMT but you would know to multiply that number by 10.

This may be a viable option as it would still allow you to test for geometrical effects etc. albeit with lower statistical accuracy.