Dear all, 

I checked the example findind probably related to an incorrect definition of the 'root' region for the cut definition in some geometrical elements defined in the MedLinacHead.cc class file.

The problem should be related to the follow line:

CylMinusCone_log->SetRegion(aLowerCollRegion);
aLowerCollRegion->AddRootLogicalVolume(CylMinusCone_log);

//G4String regName1 = "PrimaryCollimatorUp";
//G4Region* aUpperCollRegion = new G4Region(regName1);
UpperCollimator_log->SetRegion(aUpperCollRegion);
aUpperCollRegion->AddRootLogicalVolume(UpperCollimator_log);

please try to comment all the line and check if it function.
If you have problem in the definition of cuts in your simulation, pleas cheak any other example: TestEm7 or Hadrontherapy are my suggestions for this but many other examples exist.

I made a general revision also of the physics model implementation of this example presenting at moment some old and not more supported models.
The update of the physic models will be present in the next December releaase.

If someone is interested in the updated version, please contact me directly and I'll provide you the code.

Regards,
Pablo Cirrone

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Ok: Re: medical_linac compiling problem   (paulmcg - 22 Sep, 2009)
 Add Message Add Message
to: "Re: medical_linac compiling problem"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]