Message: Two PMTs - no optical photons recorded by detector 1 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question Two PMTs - no optical photons recorded by detector 1 

Forum: Hits, Digitization and Pileup
Date: 11 Mar, 2013
From: Steve Asztalos <Steve Asztalos>

Hello,

I am modelling two PMTs using Example N05 as a template - I eventually wish to generalize it to a dodecahedron. Up front I must admit that the C++ in example LXe is a bit of a challenge for me. I notice that I never get optical photons from PMT copyNo = 1 (ouptut attached). When I turn the visualization on I see optical photons being generated in both PMTs. Does it have to do with the way I am writing the output?

I have studied the fora fairly intently, including making fCollectionHits a data member, though to no avail...

Thanks - Steve

I would really appreciate it if you would take a look at my modified files and see if I made an obvious mistake. I feel that I am so close

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2013/03/11/12.39-85121-chDetectorConstruction.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2013/03/11/12.39-39033-PhoswichPMTSD.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2013/03/11/12.39-90228-ichInnerScintillatorSD.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2013/03/11/12.39-16128-PhoswichEventAction.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2013/03/11/12.39-10073-Xe133test_data.txt

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Two PMTs - no optical photons recorded by detector 1   (Tsukasa Aso - 24 Mar, 2013)
 Add Message Add Message
to: "Two PMTs - no optical photons recorded by detector 1"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]