Message: Re: use G4PSDoseDeposit class together with variance deduction techniques Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: use G4PSDoseDeposit class together with variance deduction techniques 

Keywords: Dose, sensitive detector
Forum: Hits, Digitization and Pileup
Re: None use G4PSDoseDeposit class together with variance deduction techniques (long)
Re: None Re: use G4PSDoseDeposit class together with variance deduction techniques (Tsukasa Aso)
Date: 20 Aug, 2007
From: Tsukasa Aso <Tsukasa Aso>

Dear Long,

 Thank you for providing your code.
It looks same as the code in G4PSDoseDeposit.
In my study, both value of the dose calculated in 
G4PSDoseDeposit and SteppingAction are same each other. 
And the dose calculated with "analogueMC 0" are
not consistent with the dose calculated with "analogueMC 1".

 I checked related parameters in both of SteppingAction and
G4PSDoseDeposit, but all of them are same. So I still does not
understand what is the difference between SteppingAction 
and G4PSDoseDeposit as you reported.

 Do you have any further information about your calculation
in your SteppingAction and your analysis? I want to find
what is missed in G4PSDoseDeposit but you included 
in your SteppingAction.


 Tsukasa Aso