Message: Re: Spike in Deposited Energy/Time at Boundary of Detector Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: Spike in Deposited Energy/Time at Boundary of Detector 

Forum: Hits, Digitization and Pileup
Re: Question Spike in Deposited Energy/Time at Boundary of Detector (Sean Lourette)
Re: None Re: Spike in Deposited Energy/Time at Boundary of Detector (Sean Lourette)
Date: 30 Aug, 2006
From: Vladimir IVANTCHENKO <vnivanch@mail.cern.ch>

On Thu, 17 Aug 2006, Sean Lourette wrote:

> *** Discussion title: Hits, Digitization and Pileup
> Email replies to PublicHyperNews@slac.stanford.edu must include:
>   In-Reply-To: <"/hitsdigits/133/1"@geant4-hn.slac.stanford.edu>
>   Subject: ...change this to be about your reply.
> 
> I just discovered that the Transportation process was occasionally
> depositing energy. When I sift out the energy that it deposits, it
> removes the final spike in the graph (the second of the two spikes at
> the back of the detector). How can I fix this problem?
> 

Transportation limiting the step, energy is deposited due to ionisation. 
Please, post your problem in em forum

VI