Message: Re: bug in geant4 9.2 ? helium counter, energies of secondaries. Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: bug in geant4 9.2 ? helium counter, energies of secondaries.  

Forum: Hadronic Processes
Re: Question bug in geant4 9.2 ? helium counter, energies of secondaries. (Marcin Kasztelan)
Date: 06 Feb, 2009
From: Koi, Tatsumi <Koi, Tatsumi>

Hi Marcin, Thank you for reporting this problem. The reaction(n-3He->p+T) Q value from Geant4 nuclear masses become 1273keV. If we use masses of AME2003, then the Q value becomes your value 763keV. I did not expect this level difference between them. The reason is clear, however more investigation required for fix. Does some one do full comparison nuclear mass (or atomic mass) of Geant4 to AME2003?

Tatsumi

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: bug in geant4 9.2 ? helium counter, energies of secondaries.   (Koi, Tatsumi - 05 Mar, 2009)
(_ None: Re: bug in geant4 9.2 ? helium counter, energies of secondaries.   (Marcin Kasztelan - 05 Mar, 2009)
 Add Message Add Message
to: "Re: bug in geant4 9.2 ? helium counter, energies of secondaries. "

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews