From: Stephanie Hickford <svh13@student.canterbury.ac.nz>

I am using novie example N04 in GEANT 4.9.1 to simulate high energy interactions regarding the decay of pions and kaons. For some of my simulations I get the following error message:

G4EnergyRangeManager:GetHadronicInteraction: counter=1, Ek=1.3088074e+08, Material = Ice, Element = Oxygen

*0* low=0, high=1e+08

In src/G4EnergyRangeManager.cc, line 123:

===> GetHadronicInteraction: No Model found

I have encounted an error message similar to this before. In that case there was more information given about which particle exceeded the upper limit of the energy range for the model (it was pions and kaons). To stop the program from crashing I added the following line to source/physics_lists/builders/src/G4QGSPPiKBuilder.cc :

theModel->SetMaxEnergy(200*TeV);

I would like to do a similar thing to fix this error message I am getting. Since the error message I am getting now does not tell me what type of particle is is exceeding the energy range of the model I am not sure what part of the source code needs to be changed. (I did not get this version of error message without the additional information about the particle when running GEANT 4.8). Can anybody help me with this problem?

Thanks, Stephanie

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Extending the Energy Range in G4EnergyRangeManager   (Dennis H. Wright - 28 Mar, 2008)
 Add Message Add Message
to: "Extending the Energy Range in G4EnergyRangeManager"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]