Dear Cirrnoe:
thank you for your responce!
In my visualisation, I can see the obvious red tracks which are 
secondary electrons and green tracks which are the gamma rays in Phantom when 
I use 250 Mev proton.
But in Patient I can't see the either red or green tracks except 
the proton beams in blue colour for 250 Mev Proton beams ( Proton can pass
Phantom and go through the patient). From the HadrontherapyDetectorConstruction.cc, 
both Phantom and Patient refered to the same water. So I didn't see
any interaction between proton and patient.   

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: Why no attenuation in patient in Hadrontherapy example?   (G.A.P.Cirrone - 01 Feb, 2008)
1 Agree: Re: Why no attenuation in patient in Hadrontherapy example?   (jfgao@mdanderson.org - 01 Feb, 2008)
4 Agree: Re: Why no attenuation in patient in Hadrontherapy example?   (jfgao@mdanderson.org - 01 Feb, 2008)
6 None: Re: Why no attenuation in patient in Hadrontherapy example?   (jgzm6@umr.edu - 01 Feb, 2008)
1 None: Re: Why no attenuation in patient in Hadrontherapy example?   (G.A.P.Cirrone - 04 Feb, 2008)
...