Message: Re: Missing C-12 gamma spectrum peak Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Feedback Re: Missing C-12 gamma spectrum peak 

Keywords: Gamma spectrum, precompound model, carbon, physics list
Forum: Hadronic Processes
Re: Question Missing C-12 gamma spectrum peak (Steve Peterson)
Date: 14 Jan, 2008
From: Gunter Folger <Gunter Folger>

Hello,

the precompound model should produce some gamma lines for Carbon12; more precisely, the nuclear de-excitation models used by precompound knows about these discrete lines. The environment variable G4LEVELGAMMADATA pointing to the data files containing information on these gamma lines must be set, can you please check that you have files under $G4LEVELGAMMADATA, and that specifically there is a file named z6.a12.

Also, in releases 9.0 and also in 9.1 we corrected several problems in the deexcitation code, I'd recommend you try your code with 9.1.

Gunter

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: Missing C-12 gamma spectrum peak   (Steve Peterson - 17 Jan, 2008)
 Add Message Add Message
to: "Re: Missing C-12 gamma spectrum peak"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]