Message: Re: G4NeutronRadCapture produces incorrect secondary particles Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: G4NeutronRadCapture produces incorrect secondary particles 

Forum: Hadronic Processes
Re: Question G4NeutronRadCapture produces incorrect secondary particles
Date: 19 Oct, 2016
From: michel maire <michel maire>

On Fri, 14 Oct 2016 17:10:00 GMT, adamrouh wrote:
> I am trying to simulate neutron activation of Li6: n + Li6 -> H3 + alpha
> + Q(4.78 MeV).
> 
> Even stranger, if the material is simply Li6, the secondary particles
> are a gamma and Li8.

 In attachment, a macro to run example Hadr03 (in extended/hadronic) and the output.
 As you can see, there is no trace of Li8

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2016/10/19/01.01-17957-Li6.mac.txt
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2016/10/19/01.01-7396-Li6.out.txt

 Add Message Add Message
to: "Re: G4NeutronRadCapture produces incorrect secondary particles"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]