Message: Quite big disagreement of neutron moderate between MCNP and Geant4 Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Quite big disagreement of neutron moderate between MCNP and Geant4 

Forum: Hadronic Processes
Date: 08 Jul, 2016
From: Liyong Zhang <Liyong Zhang>

Hi all,

I am using Geant4 to simulate the 2.25 MeV neutron source at the center of a heavy water ball. Geant4 shows the protons will be all absorbed when the radius larger than 60 cm. However, the MCNP shows even with radius 200 cm only 24% neutron were absorbed.

My codes originated from Hadr04, only changed the geometry from box to ball. If I don't use the capture process, I got almost the same result with MCNP

Any one has any idea about which one is right? My codes and the result were attached

Many thanks,

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2016/07/08/10.18-6143-DetectorConstruction.cc
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2016/07/08/10.18-6637-result.jpg