Message: INCLXX plus ABLA/PRECO Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Note INCLXX plus ABLA/PRECO 

Forum: Hadronic Processes
Date: 24 Feb, 2016
From: Alexey Solovyev <Alexey Solovyev>

Hello, I found the example of coupling INCLXX with ABLA in BookForAppliDev.pdf on p. 193, where it simply registered with theINCLInterface->SetDeExcitation(theAblaInterface);

On the other side, e.g. at source/physics_lists/builders/src/G4INCLXXProtonBuilder.cc the Precompound model registered both as the INCLXX parameter (theModel = new G4INCLXXInterface(thePreCompoundModel);) and independently as the model for ProtionInelasticProcess (aP->RegisterMe(thePreCompoundModel);)

Should I also register theAblaInterface same way as the Precompound model as independent process? And what will happen, for example, if I take G4HadronPhysicsINCLXX() in my physics list, and than shift to use ABLA as suggested if AppliDev manual. Whether all 3 cascades will be used (PRECO < 2 MeV because it registered, INCLXX+ABLA > 1 MeV because I shifted it)?

And what will happen if I use /process/had/inclxx/useAbla in the same case of G4HadronPhysicsINCLXX() where PRECO registered by default?

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 None: Re: INCLXX plus ABLA/PRECO   (Davide Mancusi - 03 Mar, 2016)
(_ None: Re: INCLXX plus ABLA/PRECO   (Alexey Solovyev - 04 Mar, 2016)
(_ None: Re: INCLXX plus ABLA/PRECO   (Davide Mancusi - 04 Mar, 2016)
(_ None: Re: INCLXX plus ABLA/PRECO   (Alexey Solovyev - 04 Mar, 2016)
(_ None: Re: INCLXX plus ABLA/PRECO   (Davide Mancusi - 04 Mar, 2016)