Hello,

For a proton induced activation study I would like to record not all the unstable isotopes, but only those which could produce a certain dose outside the investigated volume (so those undergoing alpha-decay should not count).

I would be very grateful if you could please let me know if such a selection of unstable isotopes could be done in SteppingAction, using the RadioactiveDecay data or any other method.

Thank you,

Cristian

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: record only the gamma and X-ray emitting isotopes   (Vladimir Ivanchenko - 21 Feb, 2016)
(_ Ok: Re: record only the gamma and X-ray emitting isotopes   (Cristian Bungau - 24 Feb, 2016)