Message: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Warning Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion 

Forum: Hadronic Processes
Re: Warning RadioactiveDecay lacks factor ln(2) in decay width-half life conversion (Mikhail)
Date: 21 Oct, 2015
From: Vladimir Ivanchenko <Vladimir Ivanchenko>

Hello Mikhail,

please, make a bug report in bugzilla: http://bugzilla-geant4.kek.jp/ 

try to do this asap because this will help to include fix in coming release and to patches for the previous releases.

VI

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Warning: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Mikhail - 21 Oct, 2015)
2 None: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Mikhail - 21 Oct, 2015)
 Add Message Add Message
to: "Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews


[ Geant 4 Home | Geant 4 HyperNews | Search | Request New Forum | Feedback ]