Message: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Warning RadioactiveDecay lacks factor ln(2) in decay width-half life conversion 

Forum: Hadronic Processes
Date: 21 Oct, 2015
From: Mikhail <Mikhail>

RadioactiveDecay database seems to have wrong conversion from decay width into half-life: factor ln(2) is missing. In fact, when the value is divided by ln(2) to get mean lifetime it return a number different from expected.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Warning: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Vladimir Ivanchenko - 21 Oct, 2015)
1 Warning: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Mikhail - 21 Oct, 2015)
2 None: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Mikhail - 21 Oct, 2015)
2 None: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (michel maire - 21 Oct, 2015)
1 None: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Mikhail - 21 Oct, 2015)
3 None: Re: RadioactiveDecay lacks factor ln(2) in decay width-half life conversion   (Dennis H. Wright - 24 Oct, 2015)