Message: Re: RDM not decaying Sr-85 properly Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None Re: RDM not decaying Sr-85 properly 

Forum: Hadronic Processes
Re: Question RDM not decaying Sr-85 properly (Glen Warren)
Date: 14 Apr, 2015
From: michel maire <michel maire>

On Mon, 13 Apr 2015 20:53:58 GMT, Glen Warren wrote:
> I'm running version 9.6.p02 on OS X 10.8.5, using RadioactiveDecay 3.6.
> When use the RadioactiveDecayModule (RDM) to generate decay particles
> for decaying isotopes for a lot of individual isotopes. In recent tests,
> I do not see the 514-keV gamma coming from Sr-85. Is it me, or is there
> something else going on?
> 

  Here a macro, an output and a gamma plot from example rdecay01

   Attachment:
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2015/04/14/03.07-45257-Sr85.mac.txt
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2015/04/14/03.07-30339-Sr85.out.txt
      http://hypernews.slac.stanford.edu/HyperNews/geant4/get/AUX/2015/04/14/03.07-96958-Sr85.gif