On Mon, 22 Dec 2014 12:10:03 GMT, Hubert Chiron wrote:
> Dear geant4 users
> 
> I use Geant4-10.00.p01 and rdecay02 example for my simulation.
> With nucleus 109Cd and 207Bi, I've got in my detector a sum of gamma and
> x-rays.
> 
> For example with 207Bi:
> gamma 1036 keV + XR kalpha1 74.9 keV
> gamma 1036 keV + XR kalpha2 72.8 keV
> 
> and with 109Cd:
> gamma 88 keV + XR kalpha1 22.16 keV
> 
> is it normal or impossible ?
> 
> best regards
> 
> Hubert
> 
 The XR comes from atomic relaxation (ARM option) which follow an internal conversion.
 If you switch off this option, the X ray will disappear.
 See rdecay01: PhysicList.cc 

     Michel