Message: Re: wrong momentum distribution of secondary after neutron capture Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Idea Re: wrong momentum distribution of secondary after neutron capture 

Forum: Hadronic Processes
Re: None wrong momentum distribution of secondary after neutron capture (Michael Gericke)
Re: Idea Re: wrong momentum distribution of secondary after neutron capture (filippo)
Re: More Re: wrong momentum distribution of secondary after neutron capture (Michael Gericke)
Date: 07 Sep, 2014
From: filippo <filippo>

Hi,

if you are using NeutronHP or thermal scattering implementation (as me :) ) you may find useful this document I've found a couple of days ago:

http://wwwae.ciemat.es/~arce/particle_hp/BriefInstructions_G4NeutronHP_v5.pdf

At the begin of the third page there's something concerning ENV variables in particular:

G4NEUTRONHP_DO_NOT_ADJUST_FINAL_STATE

It is about energy and momentum conservation.

An example of variables setting can be found in example Hadr04.

Hope this can help you in some way...

Best regards

Filippo

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: wrong momentum distribution of secondary after neutron capture   (Vladimir Ivanchenko - 08 Sep, 2014)
 Add Message Add Message
to: "Re: wrong momentum distribution of secondary after neutron capture"

 Subscribe Subscribe

This site runs SLAC HyperNews version 1.11-slac-98, derived from the original HyperNews