Message: Re: wrong momentum distribution of secondary after neutron capture Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

More Re: wrong momentum distribution of secondary after neutron capture 

Forum: Hadronic Processes
Re: None wrong momentum distribution of secondary after neutron capture (Michael Gericke)
Re: Idea Re: wrong momentum distribution of secondary after neutron capture (filippo)
Date: 03 Sep, 2014
From: Michael Gericke <Michael Gericke>

Hi Filippo,

Thank you for responding to my question.

What I want is the momentum direction the track had at the start of the track (e.g. at the vertex), not for a given step.

In any case, no matter where I get it from, for the physics I am looking at, the momentum distribution should be isotropic; Very low energy -> no boost and capture at rest on top of that ...

I spent the better part of the day, trying to find other ways to implement my physics, but to no avail ... something is fishy ...

For now, I am resorting to reassigning a new momentum direction in tracking action, which I find rather unsettling.

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: wrong momentum distribution of secondary after neutron capture   (filippo - 07 Sep, 2014)
(_ Idea: Re: wrong momentum distribution of secondary after neutron capture   (Vladimir Ivanchenko - 08 Sep, 2014)
 Add Message Add Message
to: "Re: wrong momentum distribution of secondary after neutron capture"

 Subscribe Subscribe