Message: characteristic X-ray Energy Problem from muon capture Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

None characteristic X-ray Energy Problem from muon capture 

Forum: Hadronic Processes
Date: 18 Nov, 2011
From: Yoshi <Yoshi>

Hi,all

I have problem with muon capture simulation. Energy of characteristic X-ray by muon capture is different from experimental values.

For example,Target matter is Fe,Al,Si and Pb.

             experiment(keV)       Geant4 round off(keV)
56Fe(2p-1s)   1253.06 , 1257.19         1234  
    (3d-2p)   265.7 , 269.4              263  
27Al(2p-1s)    346.828                   340   
    (3d-2p)    66.11                      66  
28Si(2p-1s)    400.177                   387   
    (3d-2p)    76.723                     76  
208Pb(2p-1s)   5778.1 ,5962.9            5673  

Experimental energy(2p-1s) of Fe has two value,but geant4 give me only one value. I think that the energy of characteristic X-ray from Geant4 may not by correct. Please fix it.

Yoshi

Inline Depth: