Message: thermal neutron capture - show 411keV gamma Not Logged In (login)
 Next-in-Thread Next-in-Thread
 Next-in-Forum Next-in-Forum

Question thermal neutron capture - show 411keV gamma 

Forum: Hadronic Processes
Date: 22 Jun, 2011
From: Sean Turnbull <Sean Turnbull>

Hello all,

I am modelling muons incident on a lead shield creating neutrons which activate a Gold disk. I can see Au198 isotopes produced and can output this:

if ( particleValue == 1000791980 )
{
   G4cout << " Au198 Isotope: " << particleName << " particle encoding " << particleValue << G4endl;
}

Au198 Isotope: Au198[0.0] particle encoding 1000791980.

What I am needing now is a check to see that a 411.8 keV gamma quantum follows a capture of a thermal neutron. Would that be best to do in the Stepping action? I am worried that it could be quite an intensive search as there will be many secondaries in the reaction.

I am also using the QGSP_BIC_HP list.

Thanks for any help

Inline Depth:
 1 1
 All All
Outline Depth:
 1 1
 2 2
 All All
Add message: (add)

1 Idea: Re: thermal neutron capture - show 411keV gamma   (Vladimir Ivanchenko - 22 Jun, 2011)
(_ Feedback: Re: thermal neutron capture - show 411keV gamma   (Sean Turnbull - 22 Jun, 2011)
(_ Feedback: Re: thermal neutron capture - show 411keV gamma   (Sean Turnbull - 24 Jun, 2011)
(_ Idea: Re: thermal neutron capture - show 411keV gamma   (Vladimir Ivanchenko - 27 Jun, 2011)
(_ Question: Re: thermal neutron capture - show 411keV gamma   (Sean Turnbull - 27 Jun, 2011)